 4-STAGE COUNTER/ SHIFT REGISTER
SY100S336
FEATURES
s s s s s s s s s s Max. shift frequency of 700MHz Clock to Q delay max. of 1100ps IEE min. of -170mA Internal 75K input pull-down resistors Industry standard 100K ECL levels Extended supply voltage option: VEE = -4.2V to -5.5V Voltage and temperature compensation for improved noise immunity 50% faster than Fairchild 300K at lower power Function and pinout compatible with Fairchild F100K Available in 24-pin CERPACK and 28-pin PLCC packages
DESCRIPTION
The SY100S336 functions either as a modulo-16 up/ down counter or as a 4-bit bidirectional shift register and is designed for use in high-performance ECL systems. Three Select inputs (Sn) are provided for determining the mode of operation. The Function Table lists the available modes of operation. In order to allow cascading for multistage counters, two Count Enable controls (CEP, CET) are provided. The CET input also functions as the Serial Data input (S0) for a shift-up operation, while the D3 input serves as the Serial Data input for the shift-down operation. When the device is in the counting mode, the Terminal Count (TC) goes to a logical LOW when the count reaches 15 for count-up or reaches 0 for count-down. When in the shift mode, the TC output simply repeats the Q3 output. The flexiblity provided by the TC/Q3 output and the D0/ CET input allows these signals to be interconnected from one stage to the next higher stage for multistage counting or shift-up operations. The individual Presets (Pn) allow initialization of the counter by entering data in parallel to preset the counter. A logic HIGH on the Master Reset (MR) overrides all other inputs and asynchronously clears the flip-flops. An additional synchronous Clear is provided, as well as a complement function which synchronously inverts the contents of the flip-flops. All inputs have 75K pulldown resistors.
PIN CONFIGURATIONS
P2 P3 VEES Q3 Q3
4 3 Top View PLCC J28-1 2 1 28 27 26 19 20 21 22 23 24 25
11 10 9 8 7 6 5 P0 CP VEE VEES MR S0 S1 12 13 14 15 16 17 18 Q2 Q2 VCCA VCC VCC Q1 Q1
D3
P1
PIN NAMES
Pin CP CEP Function Clock Pulse Input Count Enable Parallel Input (Active LOW) Serial Data Input/Count Enable Trickle Input (Active LOW) Select Inputs Master Reset Input VEE Substrate VCCO for ECL Outputs Preset Inputs Serial Data Input Terminal Count Output Data Outputs Complementary Data Outputs
S0 MR VEE
CEP D0/CET VEES
TC Q0
Q0
S2
CP P0
S1
D0/CET S0 -- S2
P1 P2 P3 D3 Q3 Q3
S2 CEP D0/CET TC Q0 Q0
24 23 22 21 20 19 1 18 2 3 4 5 6 Top View Flatpack F24-1 17 16 15 14
MR VEES VCCA P0 - P3 D3 TC Q0 -- Q3 Q0 -- Q3
13 7 8 9 10 11 12 Q1 VCC Q1 VCCA Q2 Q2
Rev.: G
Amendment: /0
1
Issue Date: July, 1999
Micrel
SY100S336
BLOCK DIAGRAM
D3
D0/CET
S0 CEP S1 S2
TC
T Q0 T Q0 R T RC
T T Q1
T T Q2 T
R Q1 T TC
R Q2 T TC
T T Q3 T T R Q3 T TC
CP MR
P0 Q0 Q0
P1 Q1 Q1
P2 Q2 Q2
P3 Q3 Q3
2
Micrel
SY100S336
TRUTH TABLE(1)
Inputs MR L L L L L L L L L L L L H H H H H H H H H S2 L L L L H H H H H H H H L L L L H H H H H S1 L L H H L L L L H H H H L L H H L L L H H S0 L H L H L L L H L L L H L H L H L L H L H CEP X X X X L H X X L H X X X X X X X X X X X D0/CET X X X X L L H X L L H X X X X X L H X X X D3 X X X X X X X X X X X X X X X X X X X X X CP u u u u u X X u u X X X X X X X X X X X X Q0 Q0 Q0 L L L L L L L L L Q0 Q0 L Q0 P0 Q0 Q1 D0 Q1 P1 Q1 Q2 Q0 Outputs Q2 P2 Q2 Q3 Q1 Q3 P3 Q3 D3 Q2 TC L L D3 Q3* x Q3 Q3 L x H H Q3 Q3 Q3 L L L L L L L L L H H L L L L L H H H H Mode Preset (Parallel Load) Invert Shift Left Shift Right Count Down Count Down with CEP Not Active Count Down with CET Not Active Clear Count Up Count Up with CEP Not Active Count Up with CET Not Active Hold Asynchronous Master Reset
(Q0-3) minus 1 Q1 Q1 L Q2 Q2 L
(Q0-3) plus 1 Q1 Q1 Q1 L L L L L L L L L Q2 Q2 Q2 L L L L L L L L L
NOTE: 1. H = High Voltage Level L = Low Voltage Level X = Don't Care u = LOW-to-HIGH Transition x = L if Q0 - Q3 = LLLL H if Q0 - Q3 LLLL = L if Q0 - Q3 = HHHH H if Q0 - Q3 HHHH * Before the clock, TC is Q3; after the clock, TC is Q2
DC ELECTRICAL CHARACTERISTICS
VEE = -4.2V to -5.5V unless otherwise specified, VCC = VCCA = GND
Symbol IIH IEE Parameter Input HIGH Current, All Inputs Power Supply Current Min. -- -170 Typ. -- -145 Max. 200 -90 Unit A mA Condition VIN = VIH (Max.) Inputs Open
3
Micrel
SY100S336
AC ELECTRICAL CHARACTERISTICS CERPACK
VEE = -4.2V to -5.5V unless otherwise specified, VCC = VCCA = GND
TA = 0C Symbol fshift tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tTLH tTHL tS Parameter Shift Frequency700 Propagation Delay CP to Qn, Qn Propagation Delay CP to TC Propagation Delay MR to Qn, Qn Propagation Delay MR to TC Propagation Delay D0/CET to TC Propagation Delay Sn to TC Transition Time300 20% to 80%, 80% to 20% Set-up Time D3 Pn D0/CET to CEP Sn MR (Release Time) Hold Time D3 Pn D0/CET to CEP Sn Pulse Width HIGH, CP, MR Min. -- 450 600 500 600 400 1500 900 Max. 700 1200 1900 1400 1900 1200 2600 300 TA = +25C Min. -- 450 600 500 600 400 1500 900 Max. 700 1200 1900 1400 1900 1200 2600 300 TA = +85C Min. -- 450 600 500 600 400 1500 900 Max. MHz 1200 1900 1400 1900 1200 2600 ps ps 800 800 700 2000 900 200 200 200 -600 -- -- -- -- -- -- -- -- -- -- 800 800 800 700 2000 900 200 200 200 -600 -- -- -- -- -- -- -- -- -- -- 800 800 800 700 2000 900 200 200 200 -600 -- -- -- -- -- -- ps -- -- -- -- 800 ps ps ps ps ps ps ps Unit Condition
tH
tpw (H)
4
Micrel
SY100S336
AC ELECTRICAL CHARACTERISTICS PLCC
VEE = -4.2V to -5.5V unless otherwise specified, VCC = VCCA = GND
TA = 0C Symbol fshift tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tTLH tTHL tS Parameter Shift Frequency700 Propagation Delay CP to Qn, Qn Propagation Delay CP to TC Propagation Delay MR to Qn, Qn Propagation Delay MR to TC Propagation Delay D0/CET to TC Propagation Delay Sn to TC Transition Time 20% to 80%, 80% to 20% Set-up Time D3 Pn D0/CET to CEP Sn MR (Release Time) Hold Time D3 Pn D0/CET to CEP Sn Pulse Width HIGH, CP, MR Min. -- 450 600 500 600 400 1500 300 Max. 700 1100 1800 1300 1800 1100 2500 900 TA = +25C Min. -- 450 600 500 600 400 1500 300 Max. 700 1100 1800 1300 1800 1100 2500 900 TA = +85C Min. -- 450 600 500 600 400 1500 300 Max. MHz 1100 1800 1300 1800 1100 2500 900 ps ps ps ps ps ps ps ps 800 800 700 2000 900 200 200 200 -600 -- -- -- -- -- -- -- -- -- -- 800 800 800 700 2000 900 200 200 200 -600 -- -- -- -- -- -- -- -- -- -- 800 800 800 700 2000 900 200 200 200 -600 -- -- -- -- -- -- ps -- -- -- -- 800 ps Unit Condition
tH
tpw (H)
5
Micrel
SY100S336
TIMING DIAGRAMS
DATA
0.7 0.1 ns
0.7 0.1 ns -0.95V 80% 50% 20% -1.69V
CLOCK
1/fshift tPHL tPLH
tpw (H)
OUTPUT
50%
tPLH
tPHL
OUTPUT
tTLH
tTHL
Propagation Delay (Clock) and Transition Times
0.7 0.1 ns
0.7 0.1 ns -0.95V 80% 50% 20% -1.69V tS (RELEASE TIME) tpw (H)
MR
CLOCK
50%
tPHL
tPLH
OUTPUT
50%
tPLH
tPHL 80% 50% 20%
OUTPUT
Propagation Delay (Reset)
6
Micrel
SY100S336
TIMING DIAGRAMS
0.7 0.1 ns INPUT 80% 50% 20% -1.69V tPHL tPLH 80% 50% 20% tTLH tTHL 0.7 0.1 ns -0.95V
OUTPUT
Propagation Delay (Serial Data, Selects)
INHIBIT COUNT -0.95V CEP 50% -1.69V ENABLE COUNT tH tS -0.95V D3, Pn, Sn 50% -1.69V tH tS -0.95V CLOCK 50% -1.69V
Set-up and Hold Time NOTES: 1. VEE = -4.2V to -5.5V unless otherwise specified, VCC = VCCA = GND. 2. tS is the minimum time before the transition of the clock that information must be present at the data input. 3. tH is the minimum time after the transition of the clock that information must remain unchanged at the data input.
PRODUCT ORDERING CODE
Ordering Code SY100S336FC SY100S336JC SY100S336JCTR Package Type F24-1 J28-1 J28-1 Operating Range Commercial Commercial Commercial
7
Micrel
SY100S336
24 LEAD CERPACK (F24-1)
Rev. 03
8
Micrel
SY100S336
28 LEAD PLCC (J28-1)
Rev. 03
MICREL-SYNERGY
TEL
3250 SCOTT BOULEVARD SANTA CLARA CA 95054 USA
FAX
+ 1 (408) 980-9191
+ 1 (408) 914-7878
WEB
http://www.micrel.com
This information is believed to be accurate and reliable, however no responsibility is assumed by Micrel for its use nor for any infringement of patents or other rights of third parties resulting from its use. No license is granted by implication or otherwise under any patent or patent right of Micrel Inc. (c) 2000 Micrel Incorporated
9


▲Up To Search▲   

 